Hornsby Shire Council have introduced an innovative custom-built heating and ventilation system at the Galston Aquatic and Leisure Centre in Sydney’s Hills District. The ‘PoolPac Plus’ system was created by Air Change to meet council’s requirements for: improved air quality and energy efficiency; reduced costs for heating, ventilation and maintenance; and long term sustainability through better management systems. The PoolPac Plus is a direct expansion (DX) heat pump system designed to control the air temperature, humidity and the pool water temperature in a single packaged unit.

The pre-existing system comprised a direct exchange air handling unit with a typical pool water heat pump using outside air as the heat source for pool water heating supplemented by a bottled gas water heater. It lacked any outside air ventilation or air temperature control.

Heated indoor pools lose water and heat from the pool water surface continuously because of evaporation leading to concentration of harmful air born chemicals and humidity in the pool environment.

In chlorinated pools, chloramines are produced when bodily proteins such as skin and sweat react with chlorine and evaporate into the pool air breathed by swimmers and workers. These chloramines are a major cause of childhood asthma and cause lung damage equivalent to smoking, as well as skin and eye irritation. Fresh air is necessary to dilute the internal air and reduce the concentration of harmful chemicals. The Australian standard requires the Galston Aquatic Centre to extract and replace 4000 litres per second of exhaust air.

In addition it is important to control the temperature and relative humidity in the swimming pool hall for the comfort of the pool workers and non-swimmers.

High relative humidity causes condensation to form on cold surfaces leaving a corrosive liquid which can cause major damage to the building fabric, pool plant and equipment, brackets for suspended light fittings, loudspeakers, pipe work, conduits, rod/bar supports for ventilation ducts, water slides and other features, including fasteners and wire rope supports for water slides.

Directing warm supply air from the pool air-handling unit onto external windows and wall surfaces can also help to increase their temperature and reduce condensation. Finally, limiting the relative humidity of the indoor pool air and maintaining the air above its dewpoint (temperature /relative humidity) eliminates the risk of condensation occurring. Precise temperature and relative humidity control is essential to ensure a safe, efficient and comfortable environment.

Air Change have been designing and manufacturing swimming pool air heating systems for more than 15 years using air to air heat recovery and now offers a single unit solution to heat both air and water in enclosed heated swimming pools.

The PoolPac Plus system ventilates the space by supplying fresh outside air into the pool hall, while simultaneously exhausting the moisture laden chlorinated indoor air. More importantly, it uses this hot moist air as an efficient heat source for a Direct Expansion (DX) heat pump system to heat both the pool air and water.

Air to air heat recovery is very efficient and can extract up to 75% of the heat in the exhaust air with minimum energy consumption. The Direct Expansion heat pump recovers the remaining heat from the exhaust air and uses this energy to heat the pool water or air as required. By using this warm exhaust air as the heat source in the winter months, the PoolPac Plus can use less than half of the energy of the traditional water heat pump and perform effectively without the need to “defrost’.

The PoolPac Plus uses a sophisticated control system to prioritise heating during off-peak times and minimise energy use during peak network demand times at the aquatic centre. This load shedding can be quite easily achieved in swimming pools due to their inherently large thermal mass of water. The swimming pool temperature can be raised very slightly during times when power is inexpensive, and heating can be reduced or completely turned off during peak periods.
Energy modelling showed in advance that this system would provide major energy savings while providing the necessary ventilation, superior indoor air quality and reducution of relative humidity to prevent corrosion and damage to the building structure.

To establish the success of the PoolPac Plus installation, it is important that the system be continually monitored for both energy and heating performance. Over the past six months of monitoring, the system clearly meets the requirements of the Council. There is evidential improvement of air quality in the pool hall and a significant reduction in energy use and costs.
*Copy supplied by Air Change

Digital Editions


  • Grants close soon

    Grants close soon

    Queensland councils have until 31 March to apply for Round two of the State Government’s Secure Communities Partnership Program, which offers up to $400,000 per…

More News

  • Stretching for a good cause

    Stretching for a good cause

    Ballarat residents stretched, smiled and snuggled their way through a unique Kitten Yoga event that combined relaxation with a heartwarming cause – helping kittens find their forever homes. Hosted by…

  • Murray Library upgrade open

    Murray Library upgrade open

    The Murray Library refurbishment is now complete, and the revitalised space is officially open to the community. The upgrade delivers a brighter, more accessible and flexible library that reflects the…

  • Lockyer announce Scott Greensill as CEO

    Lockyer announce Scott Greensill as CEO

    Lockyer Valley Regional Council has appointed Scott Greensill as its new Chief Executive Officer. Councillors formally approved the appointment of Mr Greensill at a Special Meeting of Council in February.…

  • Myers resigns for health reasons

    Myers resigns for health reasons

    Wollongong’s Councillor Tiana Myers has resigned, as a Ward Three Councillor for City Council due to health reasons. Cr Myers was elected to Council in 2024 with a focus on…

  • Acknowledging women’s role in councils

    Acknowledging women’s role in councils

    Council representatives from across the state gathered in Sydney today for Local Government NSW’s (LGNSW) International Women’s Day event. Mayor Darcy Byrne, President of LGNSW, said the event was an…

  • Kylie Davies beats strong field

    Kylie Davies beats strong field

    Flinders Shire Council is pleased to announce the appointment of Kylie Davies as its new Chief Executive Officer. Ms Davies will start in the role on 13 April following a…

  • Leaving on a high

    Leaving on a high

    Mount Alexander Shire Council’s Chief Executive Officer Darren Fuzzard will end his tenure at the council in July 2026, marking ten years of service to the organisation and community. Mr…

  • Safety first for transport corridor

    Safety first for transport corridor

    Traversing a major Townsville transit corridor spanning three suburbs will soon be safer for motorists, cyclists and pedestrians, with Townsville City Council commencing a $3.8 million upgrade of Hugh and…

  • Creating long-term employment pathways

    Creating long-term employment pathways

    The Shire of Carnarvon is creating long-term employment pathways and strengthening workforce capability through its participation in the Remote Jobs and Economic Development (RJED) Program, a national initiative designed to…

  • Cool summer plan for Campbelltown

    Cool summer plan for Campbelltown

    Extreme heat is the biggest killer of natural disasters in Australia, exceeding that for any other environmental disaster combined, including floods, storms, bushfires and cyclones. While high temperatures pose risks…